Error synchronizing message ‘OBA Settings’ after installing HF1 / SP1

This was an interesting issue I encountered when troubleshooting a Duet 1.0 client after installing HF1 (the update from the following article): 928954    Description of the Duet for Microsoft Office and SAP hotfix package: December 3, 2006 http://support.microsoft.com/default.aspx?scid=kb;EN-US;928954 Symptoms: —————————————— After installing Duet HF1, deployment fails and clients become "secondary" Duet clients. We also saw…

1

Outlook Forms – Troubleshooting one-off behavior

Here are some suggestions to help identify and eliminate the cause of one-off behavior when working with Outlook forms. 1. While in design mode, make sure “Send Form Definition with Item” is not checked on the “Properties” page/tab of your custom form. If it is checked, uncheck it and re-publish the form. “Send Form Definition with Item” tells…

0

DST: CDO 1.21 issue related to having Outlook installed on Exchange Server

SYMPTOMS: ======================== I recently assisted with a CDO 1.21 DST related issue where custom date field values set programmatically with CDO 1.21 (after the DST change on 3/11) were off by 1 hour. The CDO 1.21 code was running in a Scripting Agent on an Exchange 5.5 Server that had all of the DST updates…

1

Finding appointments within a specific time frame

When programmatically searching for Appointments within a given time frame, it may seem logical to search for items that Start at the Start of your time frame and End at the End of your time frame. For example using a restriction similar to this with the Outlook Object Model:           [Start] >= MyStartDate AND [End] <= MyEndDate…

5