SCCM 2007: Management Point ekler iken alınan hata


 

How to / Nasıl yaparım:

Alınan hata: MP yüklü olmadığı halde

Another version of this product is already installed. Installation of this version cannot continue. To configure or remove the existing version of this product, use Add/Remove Programs on the Control Panel.

{B391E30E-C8BD-41FC-8B8C-540C4365DBE0}

MPmsi.log:

MSI (s) (E0:EC) [12:10:37:878]: Command Line: CCMINSTALLDIR=D:\Program Files\SMS_CCM CCMSERVERDATAROOT=D:\Program Files\Microsoft Configuration Manager USESMSPORTS=TRUE SMSPORTS=80 USESMSSSLPORTS=TRUE SMSSSLPORTS=443 USESMSSSL=TRUE SMSSSLSTATE=0 CCMENABLELOGGING=TRUE CCMLOGLEVEL=1 CCMLOGMAXSIZE=1000000 CCMLOGMAXHISTORY=1 CURRENTDIRECTORY=D:\Program Files\Microsoft Configuration Manager\bin\i386 CLIENTUILEVEL=3 CLIENTPROCESSID=5468

MSI (s) (E0:EC) [12:10:37:878]: Product Code passed to Engine.Initialize:           ''

MSI (s) (E0:EC) [12:10:37:878]: Product Code from property table before transforms: '{B391E30E-C8BD-41FC-8B8C-540C4365DBE0}'

MSI (s) (E0:EC) [12:10:37:878]: Product Code from property table after transforms:  '{B391E30E-C8BD-41FC-8B8C-540C4365DBE0}'

MSI (s) (E0:EC) [12:10:37:878]: Product registered: entering maintenance mode

MSI (s) (E0:EC) [12:10:37:878]: PROPERTY CHANGE: Adding ProductState property. Its value is '5'.

MSI (s) (E0:EC) [12:10:37:878]: PROPERTY CHANGE: Adding ProductToBeRegistered property. Its value is '1'.

MSI (s) (E0:EC) [12:10:37:878]: Entering CMsiConfigurationManager::SetLastUsedSource.

MSI (s) (E0:EC) [12:10:37:878]: Note: 1: 1402 2: UNKNOWN\Net 3: 2

MSI (s) (E0:EC) [12:10:37:878]: Specifed source is not already in a list.

MSI (s) (E0:EC) [12:10:37:878]: User policy value 'SearchOrder' is 'nmu'

MSI (s) (E0:EC) [12:10:37:878]: Machine policy value 'DisableBrowse' is 0

MSI (s) (E0:EC) [12:10:37:878]: Machine policy value 'AllowLockdownBrowse' is 0

MSI (s) (E0:EC) [12:10:37:878]: Adding new sources is allowed.

MSI (s) (E0:EC) [12:10:37:878]: PROPERTY CHANGE: Adding PackagecodeChanging property. Its value is '1'.

MSI (s) (E0:EC) [12:10:37:894]: Note: 1: 1729

MSI (s) (E0:EC) [12:10:37:894]: Note: 1: 2729

MSI (s) (E0:EC) [12:10:37:894]: Note: 1: 2729

MSI (s) (E0:EC) [12:10:37:894]: Product: SMS Management Point -- Configuration failed.

 

MSI (s) (E0:EC) [12:10:37:894]: MainEngineThread is returning 1638

Another version of this product is already installed.  Installation of this version cannot continue.  To configure or remove the existing version of this product, use Add/Remove Programs on the Control Panel.

{B391E30E-C8BD-41FC-8B8C-540C4365DBE0}

MSI (c) (5C:DC) [12:10:38:004]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied.  Counter after decrement: -1

MSI (c) (5C:DC) [12:10:38:004]: MainEngineThread is returning 1638

=== Verbose logging stopped: 7/24/2013  12:10:38 ===

Sorun kaynağı:

Registry üstünde MP olmadığı halde mevcut olan anahtar

Çözüm:

-MP yi SCCM den kaldır

-Registry aç ve “SMS Management Point” arat. Bulunan yüm anahtarları sil

-Sunucyu yeniden çalıştır

-MP tekrar ekle