OpsMgr 2007 R2 - Alert Storm Recognition (possible rule misconfiguration) for SDK alert

I described the mitigation for alert storm in the one of my previous post. This mitigation is included out of the box with current deployment of OpsMgr 2007 R2 after system management packs were imported. As I failed to remember this post (which talks about how to insert alerts from SDK), I also failed to…

0

What is new: OpsMgr 2007 R2 - How to reset monitor state with recovery?

Cameron had a nice example of using new R2 feature process monitoring in real life, but that raised a question about feature he wanted to use. Following is report of his issue and how we can help him to address his challenges using already existing feature of OpsMgr 2007.   Scenario: Monitoring a system with…

2

How to: Reset monitor when closing alert?

Not something I recommend, one would say I almost regret we did not prohibit closing alerts generated by monitor (especially when auto-resolve feature was used). But recently I learned about some ticketing systems closing alerts where it is unclear if issue was corrected, so I see some necessity to automate the action of resetting monitor…

2

Computer group and dependency health rollup in OpsMgr 2007 R2 Beta release

… will be broken when you need to create group while inheriting from Microsoft.SystemCenter.ComputerGroup. <ClassTypes>   <ClassType ID=”TestCompterGroup.Group” Accessibility=”Public” Abstract=”false” Base=”SystemCenter!Microsoft.SystemCenter.ComputerGroup” Hosted=”false” Singleton=”true” /> </ClassTypes>   This was caused by disabling all dependency monitors defined for abstract managed entity type representing computer group while trying to minimize traffic from agent to server. <DependencyMonitor ID=”Microsoft.SystemCenter.ComputerGroup.AvailabilityRollup” Accessibility=”Public”…

0

Where is thy instance monitored and how that affects dependency monitor state?

This area is rather complex and multiple factors weight in while configuration service makes the final decision, but I will try to provide somewhat simplified, rule of thumbs examples/points to help to make an educated guess while troubleshooting some state issues. I will start with dependency monitor.   Dependency monitor Dependency monitor is used to…

2

HealthServiceWatcher alerts and connector.

Recently I had heard from couple of customers (internal and external) about their trouble with ticketing alerts created from Health Service Watcher. Main complaint was related to the fact that alert is raised by instance of the watcher rather than instance of the computer that experiences a problem as well as the fact that FQDN…

0

“Net view” as diagnostic used when heartbeat is missing

This all started as question about how “Computer Not Reachable” works. It has been asked in newsgroup and I thought I will help and provide some inside. First, I would like to repeat, that in my opinion regarding the fact that computer not reachable detection is based on the fact that heart beat is missing…

3

Customizing monitor from sealed MP ("Device Status Check").

I used Device Status Check monitor in my last post when providing realistic sample of how to define alert settings thru overrides. Unfortunately, and mainly because of override value restriction regarding use of parameter replacement, description of such alert was not able to benefit from property values of its target instance (could not use device…

1

Dynamic alert settings for monitor which never had any (done thru overrides)

Tim from QuickenLoans contacted me and wanted verification about ability to use AlertMessage override (discussed in my previous post) with unit monitor for SNMP network device. He was using “Device Status Check” monitor and we can see that initial requirement for override use is met – monitor is PUBLIC. <UnitMonitor ID=”Microsoft.SystemCenter.NetworkDevice.CheckDeviceStatus” Accessibility=”Public” Target=”Microsoft.SystemCenter.NetworkDevice” Enabled=”true” TypeID=”Microsoft.SystemCenter.NetworkDevice.CheckDeviceState”…

1

Monitor from sealed MP generated alert and I do not like its description …

… Is there anything I can do? Our usual answer was that not really and you need to create your custom monitor while disabling original one. I would like to take this opportunity and rephrase that answer with this post. First, couple of requirements must be met, before I can say, that there is a…